| Perencanaan Pondasi Tiang |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dalam
perencanaan tiang bore pile dan tiang pancang mengunakan rumus yang sama
untuk |
| mendapatkan
nilai daya dukung tanah. Cuma beda di luasan dan keliling, bore pile
adalah |
| lingkaran
sedangkan untuk tiang pancang biasanya segiempat. |
|
|
|
|
|
|
|
|
|
|
|
| Rumus yang
digunakan |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (
A*qc ) / 3 + ((Keliling * JHP)/5) |
> |
V |
OK |
|
|
|
|
|
|
|
|
|
|
|
| Data dari
soil test |
|
|
|
|
|
|
|
| JHP ( Jumlah
hambatan perekat ) / Total side friction |
|
888 |
kg/cm |
| qc / Bacaan
2 |
|
|
|
|
|
200 |
kg/cm2 |
| V |
|
|
|
|
|
|
1200 |
KN |
|
|
|
|
|
|
|
120 |
Ton |
|
|
|
|
|
|
|
|
|
| Dicoba
diameter |
|
|
|
|
|
60 |
cm |
|
|
|
|
|
|
|
|
|
| (
A*qc ) / 3 + ((Keliling * JHP)/5) |
> |
V |
OK |
|
|
|
221.8598 |
|
|
> |
V |
OK |
Boros |
|
|
|
|
|
|
|
|
|
|
| Dicoba
diameter |
|
|
|
|
|
45 |
cm |
|
|
|
|
|
|
|
|
|
| (
A*qc ) / 3 + ((Keliling * JHP)/5) |
> |
V |
OK |
|
|
|
131.0699 |
|
|
> |
V |
OK |
Ideal |
|
|
|
|
|
|
|
|
|
|
| Jadi di
gunakan diameter 45 cm dengan kedalaman sesuai dengan test sondir yang
pada |
| 12 Meter.
Luas tulangan adalah 3 % dari luas tulangan lingkaran yaitu |
47.68875 |
|
Comments
silahkan mampir gan
Kami dari Usaha Karya menawarkan jasa pengerjaan pondasi dengan cara bore pile ataupun strauss pile
Dengan tenaga berpengalaman serta harga bersahabat, kami siap bekerjasama dengan anda
Email supriyadi157@gmail.com
Terimakasih
Jasa bore pile pondasi sumuran dengan mesin bore mini crane jakarta